Every machine that can hurt someone needs an emergency stop. But an E-stop is not just a red button wired to a PLC input: it must work even when the PLC, a wire or a contact fails.

2 min read · Updated 2026-10-02

The E-stop button

Why NC?

With an NC circuit, current flows when everything is OK. A pressed button, a broken wire, a loose terminal or a lost supply all give the same result: the circuit opens and the machine stops. With an NO button a broken wire would silently disable the E-stop.

Why not just the PLC?

A standard PLC can fail with its outputs stuck ON, and a program bug can ignore an input. So the E-stop must remove power from the hazards through hardware: a safety relay (or a certified safety PLC) that drives the contactors directly. The standard PLC gets a copy of the status for display and sequencing.

Safety relay basics

Stop categories (IEC 60204-1)

CategoryWhat happens
0immediate removal of power (uncontrolled stop)
1controlled stop (e.g. the drive brakes the motor), then power is removed; uses a time-delayed safety relay
2controlled stop with power left on; not allowed for an E-stop

The required safety level (PL per ISO 13849-1 or SIL per IEC 62061) comes from a risk assessment. Real safety circuits must be designed and validated by qualified people.

Other safety devices

Guard door interlock switches, two-hand control stations and safety light curtains are wired to safety relays in the same way.

The safety example in the PLC Sim Lab Playground combines an E-stop, a guard door, a light curtain and a tower light, so you can see how they interact.